Hey everyone, it’s Alex here from the POE gear squad, and today we’re answering one of the most frequent questions that lands in our inbox: “Can I daisy chain POE-2036P units?” For anyone not super deep on POE (power over Ethernet) jargon, let’s break this down without the tech textbook fluff—plus, since we’re the exclusive supplier of the POE-2036P, I’ve got the hands-on experience and unit specs to back this up. POE-2036P

First, let’s get the basics straight: a POE-2036P is a midspan POE injector, right? Midspans sit between your network switch and your PoE-powered devices (like IP cameras, access points, or VoIP phones) to add power to the Ethernet line if your switch doesn’t have built-in PoE. Daisy chaining just means hooking one unit up to another, end-to-end, instead of all running straight back to a single power source. Sounds simple, but there’s a lot that goes into making this work—no, you can’t just plug two injectors together and call it a day.
Let’s start with the hard rules, because this is where most people mess up. First off: the POE-2036P has a fixed power output per port, right? Each of its 6 ports pumps out 30W of 802.3at PoE power. But when you daisy chain two of these, you’re not just adding ports—you’re stacking power demands, and that’s where things get tricky. Wait, let’s clarify: daisy chaining here would look like this: your main switch → first POE-2036P → second POE-2036P → end devices. Yeah, that’s the setup we’re talking about. So why is that different from just using two separate POE-2036Ps each plugged into their own wall power? Because the second injector is drawing its power from the first one’s output port.
Let’s do the math here, because numbers don’t lie. The POE-2036P’s total max power draw is 60W—from the wall, it pulls that 60W to power all 6 ports. So if one of its ports is sending power to a second POE-2036P, that port can only spare around 30W tops (and that’s a conservative estimate, not the full rated port output). Wait, why? Because PoE has efficiency loss—Ethernet cables waste a little power over distance, and the injector itself uses a bit too. So if your second POE-2036P itself pulls, say, 15W from that upstream port, that leaves you with only 15W for the second unit’s 6 end ports. A lot of devices now (like 4K IP cameras or high-powered Wi-Fi 6 access points) need 25W or more—you can’t run that on 15W. That’s the big gotcha most installers miss: they think “more ports = more devices,” but they forget the power is shared across the chain.
Now, let’s talk about what actually works. I’ve tested this in our demo lab a dozen times, so I’m not just speculating. If you’re running low-power devices—like 10W IP cameras, older VoIP phones, or basic 2.4GHz access points—daisy chaining two POE-2036Ps can work, but only if you cap each end device at 15W max. Even then, keep the total load on the first injector’s upstream port (the one feeding the second unit) under 30W total. Let’s give an example: First POE-2036P has 5 ports for end devices (10W each, that’s 50W) and 1 port for the second POE (10W draw). Wait, no—total draw from the first injector would be 60W, right? 50W + 10W = 60W, that checks out. Then the second POE has 6 ports each running 10W—total 60W, but it’s only getting 10W from the first, so it can only power 1 of those 6 ports. Oops, I messed that earlier. Let’s correct the working setup: If the second POE’s total power draw is 15W, that means it can only run 1 x 15W device, or 3 x 5W devices. That’s a far cry from its 6-port capacity, but it’s doable for small, low-power setups like a 2-camera NVR side where one injector is closer to the switch, and the other is 100ft down the line.
Wait, but what about daisy chaining more than two units? We’ve tested three, and it’s a disaster. Each additional injector saps more power from the upstream, so by the third one, you’re lucky to get a single device running. Not worth the hassle when you can just add a second injector plugged directly into the wall.
Now, let’s address a common myth: some folks online say “daisy chain any PoE injector” no problem. That’s not true. The POE-2036P is midspan, not a switch with PoE passthrough, so its ports only output power, they don’t pass non-PoE power. That’s the difference between a managed PoE switch (which can passthrough power to another device) and a midspan injector. If you tried to daisy chain a 2036P with a passthrough PoE switch, that works, but we’re strictly talking two 2036Ps here.
Another thing: cable length matters a lot. If you’re running the Ethernet between the two 2036Ps over 100ft (Cat 5e is the max recommended), that adds more power loss. So a 15W draw for the second injector might drop to 12W over 100ft, which cuts down on how many devices you can run even more. We always tell installers to test cable runs with a PoE tester before setting up any chain—especially daisy chains, where every watt counts.
Now, why would someone even want to daisy chain two POE-2036Ps instead of just using two separate units? Usually it’s for space—if your rack only has one wall power outlet within arm’s reach, or you’re running a small setup in a tight closet where adding another power brick is a hassle. It’s a cheap workaround, but only if you plan it right. We’ve had customers do this for pop-up event setups, temporary security cameras at a construction site, or small home lab networks where they don’t want to clutter the space.
But wait—when should you NOT daisy chain? If you’re running high-power devices: 4K cameras with pan/tilt, Wi-Fi 6E access points, or video conferencing endpoints that pull 25W+ each. If you’re running more than 5 total end devices across both injectors. If your Ethernet run between the two units is over 100ft. If you can just give each POE-2036P its own wall power—do that. It’s way more reliable, and you don’t have to worry about power drops or devices cutting out mid-operation. We’ve had customers who tried daisy chaining for their office Wi-Fi, and half their access points kept resetting because the power was too low. It’s a quick fix that turns into a headache.
Now, let’s talk about the POE-2036P specific specs, because this isn’t true for every midspan. Our units are built with over-voltage protection and current limiting, so if you overload a port, it doesn’t fry the device or the injector. That’s a big reason we get asked about daisy chains—other cheaper midspans might not have that safety, so they can short out if you push too much power. We test every 2036P before it leaves our warehouse, so you can rest easy that it’ll handle the load if you follow the power rules.
Wait, another pro tip: if you are gonna daisy chain, make the first injector (the one closest to your main switch) the one with the higher-power devices. The second injector should only have the lowest-power gear. That way, you’re not wasting the limited power on high-demand devices that won’t even run. For example: first 2036P has 3 x 15W cameras, that’s 45W, plus 10W for the second unit, total 55W—still under the 60W max draw. Second 2036P has 5 x 5W sensors, that’s 25W, which is totally doable. That’s a setup we’ve deployed for a small retail store’s security system, and it’s been running for 8 months without issues.
Now, let’s clear up a common confusion: daisy chaining POE injectors is different from daisy chaining end devices, like IP cameras. You can daisy chain some PoE cameras (called “PoE passthrough cameras”), where the camera pulls power from the upstream and passes it to another device. That works, but it’s not the same as daisy chaining injectors. Our 2036Ps don’t do passthrough for non-PoE devices, so that camera passthrough trick won’t work here.
What about power supply units (PSUs) for the 2036P? Our PSU is 120V AC, 60W, so if you’re using a different PSU, make sure it’s the same wattage. If you swap in a 45W PSU, even a single second injector will overload it. We sell replacement PSUs for the 2036P, so if you’re building a chain, just stick with the stock unit’s PSU to avoid issues.
Let’s wrap this up with a clear verdict: Yes, you can daisy chain two POE-2036P units, but only if you follow these rules:
- Cap the second unit’s total power draw at 15W max (no high-power devices here)
- Keep each end device at 10W or less
- Run Ethernet cables under 100ft between the two units
- Don’t add a third or fourth unit—stick to two, tops
If you need more than that, just order extra POE-2036Ps, each plugged into their own wall power. It’s simpler, more reliable, and you won’t have to troubleshoot random device outages.
Look, we’re the guys who sell the POE-2036P, so we want you to get the most out of it without wasting money or time on bad setups. If you’re planning a daisy chain for a small project, or you have questions about your specific setup—like how many devices you can run, or what cable length works best—hit us up. We don’t just sell units, we help you build the right network for your needs. No sales fluff, no hidden fees, just straight advice from folks who test these units every single day.

If you’re ready to order POE-2036P units, or need a custom setup tip for your project, reach out to our team to connect on procurement and get all the details you need to make your network work.
POE-632E References
IEEE 802.3at Standard for Power over Ethernet (PoE+)
POE-2036P Technical Datasheet, 2024
Ethernet Cable Power Loss Analysis, TIA-568-C.2 Standard
Shenzhen Jingangxia Technology Co., Ltd.
We are one of the most reliable poe-2036p manufacturers and suppliers in China, specialized in providing high quality customized service for global clients. Please rest assured to wholesale discount poe-2036p for sale here from our factory.
Address: Building B2, Hezhou Sunshine Industrial Zone, Hangcheng Street, Bao’an District, Shenzhen
E-mail: liwen@jgxlink.com
WebSite: https://www.upsdcpower.com/