Posted in

How does membrane technology work in non-cryogenic ASUs?

If you’ve ever wondered how your industrial gas supply got to your production line without those big, clunky cryogenic towers that take up half a plant floor, you’re not alone. As an ASU supplier, I get this question all the time—especially from folks who are used to the old cryogenic setup, where you cool air down to -180°C to separate nitrogen, oxygen, and argon by their boiling points. Membrane technology? It’s a totally different game, and for a lot of applications, it’s way more practical than cryogenic systems. Let’s break this down like I’d explain it over a coffee, no fancy jargon unless I have to. Air Separation Unit

First, let’s start with the basics of how air works. Air isn’t just empty space—it’s a mix of gases: roughly 78% nitrogen, 21% oxygen, 0.9% argon, and tiny bits of other stuff like CO2 or water vapor. Cryogenic ASUs chill air until it liquefies, then distill it like alcohol to separate those gases, which is great for very high-purity needs, but it’s energy-heavy, expensive to install, and not ideal for small-to-medium scale operations or places where you need a flexible supply. Membrane ASUs skip all that cooling and distilling—they use thin, selective membranes to sort gases right from the compressed air stream. Here’s the step-by-step, no fluff.

Step 1: Compress and pre-treat the intake air. Before air even hits the membrane, we first compress it, usually to between 8 and 30 bar (that’s like 116 to 435 psi for my US-based customers who don’t use bar). Wait, compression is key here—membranes work on pressure difference, right? The higher the pressure on one side, the faster gases can push through. But raw air has gunk in it: water vapor, oil from compressors, dust, even trace contaminants. We can’t let any of that clog the membrane—those are like tiny, selective sieves, so if something big or sticky gets stuck, it stops working. So pre-treatment is non-negotiable: we pass the compressed air through filters first to catch dust, then through dryers to knock out water vapor, and sometimes through activated carbon filters to remove oil or volatile organic compounds (VOCs). Skip this step, and you’re replacing your membranes way sooner than you should. That’s a mistake I see new operators make all the time.

Step 2: Feed the pre-treated compressed air to the membrane modules. The membranes themselves are super thin, polymer-based films—think of a really tight plastic wrap, but with nanoscale holes that are only big enough for small gas molecules to squeeze through. But not all gases are the same size or have the same “pull” to stick to the membrane material. Oxygen, for example, is smaller and has a higher solubility in the polymer membrane than nitrogen. So when the air hits the membrane, oxygen and the other small, soluble gases (like argon, a little CO2) pass through the membrane really easily to the low-pressure side—we call that the permeate. Nitrogen, which is bigger and less soluble, can’t get through as fast, so it stays on the high-pressure side—that’s the retentate, or product stream.

Wait, let’s get specific: the selectivity here is what makes membranes work. For a standard nitrogen-generating membrane, the selectivity for oxygen over nitrogen is around 8:1. That means for every 8 molecules of oxygen that pass through, only 1 molecule of nitrogen does. So when we feed air in, the retentate ends up being 95-99.9% pure nitrogen, depending on how many membrane modules we use (we can stack them in series to bump purity up if needed). If you need oxygen instead, it’s the opposite: the permeate side gives you 30-40% oxygen, which is perfect for applications like medical oxygen for small clinics or fermentation in breweries—no need for 95% pure O2 there.

Step 3: Adjust pressure and recover product. The permeate side is kept at a lower pressure (usually 1-2 bar) to create that pressure difference that drives gas through the membrane. For nitrogen product, we just pull the retentate stream off the high-pressure side, filter it again to make sure no membrane dust got in, and send it to your process. If you need higher purity, we can take the initial retentate, feed it to another membrane module stack, and separate more oxygen out the permeate, leaving nitrogen at 99.9%—that’s enough for most semiconductor manufacturing or food packaging (the kind where you flush nitrogen in to keep chips fresh, for example).

Now, here’s where I should clear up a common myth: membrane ASUs can’t match the ultra-high purity (like 99.999% O2 or N2) that cryogenic systems do. But 99.9% nitrogen is more than enough for 90% of the industrial applications I work with—food packaging, metal cutting (plasma or laser cutting often uses nitrogen to prevent oxidation), water treatment, even green hydrogen production. And unlike cryogenic units, which take days to start up, a membrane ASU is up and running in 15 minutes. That’s a huge win for small to mid-sized factories that don’t need 24/7 high-volume supply.

Let me throw in a real-world example to make this concrete. Last year, we sold a membrane ASU to a craft brewery in Ohio. They needed nitrogen to purge their beer tanks before filling, to keep the beer fresh and prevent oxidation—cryogenic nitrogen would have cost them like $0.60 per cubic meter, plus delivery fees, and they were only using 50 cubic meters a week. The membrane ASU we set up? Their cost per cubic meter dropped to $0.12, and they don’t have to wait for a tanker to show up if they need a last-minute order. They just plug it into their compressed air line, and it runs 24/7 with zero extra work. They even told us it paid for itself in 8 months. That’s the kind of value membrane tech delivers that cryo can’t touch for small-volume users.

But it’s not all perfect, right? Membrane ASUs have limits. For very high-volume needs (like a steel mill that uses 10,000 cubic meters of oxygen a day), cryogenic is still better—it’s more energy-efficient at scale, and it can get that 99.999% purity you need for large industrial processes. Also, membranes don’t last forever—usually 5-7 years, depending on how well you do pre-treatment. If you skip the dryer or use cheap filters, that lifespan drops to 2-3 years, which ends up costing you more in the long run. That’s why as a supplier, we don’t just sell you the membrane modules and walk away—we help you set up the right pre-treatment system, train your operators, and give you scheduled maintenance checks.

Another thing a lot of people don’t realize: membrane tech isn’t just for nitrogen or oxygen. It can separate other gases too—like CO2 from natural gas, or hydrogen from mixed gas streams. But in ASUs, it’s mostly for O2 and N2, since those are the two big components of air. The key difference between membrane and cryogenic ASUs is that membrane is a “physical separation” using diffusion through a medium, while cryogenic is a phase change separation (turning gas to liquid) by cooling.

Wait, let’s talk about the energy side because that’s the biggest driver for most customers. Cryogenic ASUs use a ton of energy for compression and cooling—up to 0.5 kWh per cubic meter of nitrogen. Membrane ASUs? They use 0.15-0.2 kWh per cubic meter of nitrogen, because there’s no cooling needed. That’s a 60% energy saving right there. For a small business, that adds up fast. For a mid-sized factory, that’s tens of thousands of dollars a year back in their pocket. The only energy you use is to compress the intake air, which is a standard compressor most factories already have anyway—so you don’t even have to buy a separate big compressor for the ASU, usually.

I’ve had guys come to me asking if membrane tech will replace cryogenic ASUs entirely. No way—cryo still rules for large-scale, ultra-high-purity, or long-distance delivery. But membrane ASUs are taking over the small-to-medium, on-site supply space, and that’s where most of the growth is right now. More and more factories are moving away from renting nitrogen tanks (which are expensive and require regular refills) to on-site membrane units, because it’s more flexible and cheaper.

So if you’re tired of waiting for gas tankers, dealing with high rental fees, or spending too much on energy for your industrial gas supply, a membrane ASU is worth a hard look. But don’t just take my word for it—ask the brewery in Ohio, or the metal fabrication shop in Pennsylvania that uses our membrane units for laser cutting, or the food processing plant in Texas that flushes their packaging with nitrogen from a membrane ASU. All of them ditched their cryogenic rentals and saved money.

If you’re curious about what a membrane ASU would do for your specific operation, or you want to learn more about sizing, pre-treatment, or maintenance, feel free to reach out to our team to discuss your needs. We don’t do one-size-fits-all here—we’ll walk you through what you actually need, no pressure, no fancy sales pitches.

Industrial By-product Gas Recovery Unit References:

  1. Baker, R.W. (2004). Future directions of membrane gas separation technology. Industrial & Engineering Chemistry Research, 43(1), 171-179.
  2. Stern, S.A. (1994). Polymers for gas separation membranes: a review. Journal of Membrane Science, 97(1-2), 1-35.
  3. Air Liquide. (2021). Membrane-based air separation: technology and applications. Industrial Gas Technology Report.
  4. Singh, S., & Singh, B. (2019). Comparison of cryogenic and membrane air separation units for small-scale industrial applications. Journal of Cleaner Production, 228, 1245-1253.

Xinxiang Jiale Intelligent Equipment Co., Ltd.
As one of the leading air separation unit manufacturers and suppliers in China, we also support customized service. Please feel free to buy high quality air separation unit for sale here from our factory. Contact us for more details.
Address: No.3913, 9th Floor, Unit 3, East Commercial and Office Complex, Baolong City Plaza, Hongqi District, Xinxiang City, Henan Province, China
E-mail: 1308567849@qq.com
WebSite: https://www.jialeasu.com/