{"id":948,"date":"2026-11-22T05:50:34","date_gmt":"2026-11-21T21:50:34","guid":{"rendered":"http:\/\/www.jsbudea.com\/blog\/?p=948"},"modified":"2026-11-22T05:50:34","modified_gmt":"2026-11-21T21:50:34","slug":"can-i-daisy-chain-poe-2036p-units-4114-a8e927","status":"publish","type":"post","link":"http:\/\/www.jsbudea.com\/blog\/2026\/11\/22\/can-i-daisy-chain-poe-2036p-units-4114-a8e927\/","title":{"rendered":"Can I daisy chain POE-2036P units?"},"content":{"rendered":"<p>Hey everyone, it\u2019s Alex here from the POE gear squad, and today we\u2019re answering one of the most frequent questions that lands in our inbox: \u201cCan I daisy chain POE-2036P units?\u201d For anyone not super deep on POE (power over Ethernet) jargon, let\u2019s break this down without the tech textbook fluff\u2014plus, since we\u2019re the exclusive supplier of the POE-2036P, I\u2019ve got the hands-on experience and unit specs to back this up. <a href=\"https:\/\/www.upsdcpower.com\/dc-ups\/poe-2036p\/\">POE-2036P<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.upsdcpower.com\/uploads\/47500\/small\/protable-dc-ups-with-20000mahef131.jpg\"><\/p>\n<p>First, let\u2019s get the basics straight: a POE-2036P is a midspan POE injector, right? Midspans sit between your network switch and your PoE-powered devices (like IP cameras, access points, or VoIP phones) to add power to the Ethernet line if your switch doesn\u2019t have built-in PoE. Daisy chaining just means hooking one unit up to another, end-to-end, instead of all running straight back to a single power source. Sounds simple, but there\u2019s a lot that goes into making this work\u2014no, you can\u2019t just plug two injectors together and call it a day.<\/p>\n<p>Let\u2019s start with the hard rules, because this is where most people mess up. First off: the POE-2036P has a fixed power output per port, right? Each of its 6 ports pumps out 30W of 802.3at PoE power. But when you daisy chain two of these, you\u2019re not just adding ports\u2014you\u2019re stacking power demands, and that\u2019s where things get tricky. Wait, let\u2019s clarify: daisy chaining here would look like this: your main switch \u2192 first POE-2036P \u2192 second POE-2036P \u2192 end devices. Yeah, that\u2019s the setup we\u2019re talking about. So why is that different from just using two separate POE-2036Ps each plugged into their own wall power? Because the second injector is drawing its power from the first one\u2019s output port.<\/p>\n<p>Let\u2019s do the math here, because numbers don\u2019t lie. The POE-2036P\u2019s total max power draw is 60W\u2014from the wall, it pulls that 60W to power all 6 ports. So if one of its ports is sending power to a second POE-2036P, that port can only spare around 30W tops (and that\u2019s a conservative estimate, not the full rated port output). Wait, why? Because PoE has efficiency loss\u2014Ethernet cables waste a little power over distance, and the injector itself uses a bit too. So if your second POE-2036P itself pulls, say, 15W from that upstream port, that leaves you with only 15W for the second unit\u2019s 6 end ports. A lot of devices now (like 4K IP cameras or high-powered Wi-Fi 6 access points) need 25W or more\u2014you can\u2019t run that on 15W. That\u2019s the big gotcha most installers miss: they think \u201cmore ports = more devices,\u201d but they forget the power is shared across the chain.<\/p>\n<p>Now, let\u2019s talk about what actually works. I\u2019ve tested this in our demo lab a dozen times, so I\u2019m not just speculating. If you\u2019re running low-power devices\u2014like 10W IP cameras, older VoIP phones, or basic 2.4GHz access points\u2014daisy chaining two POE-2036Ps can work, but only if you cap each end device at 15W max. Even then, keep the total load on the first injector\u2019s upstream port (the one feeding the second unit) under 30W total. Let\u2019s give an example: First POE-2036P has 5 ports for end devices (10W each, that\u2019s 50W) and 1 port for the second POE (10W draw). Wait, no\u2014total draw from the first injector would be 60W, right? 50W + 10W = 60W, that checks out. Then the second POE has 6 ports each running 10W\u2014total 60W, but it\u2019s only getting 10W from the first, so it can only power 1 of those 6 ports. Oops, I messed that earlier. Let\u2019s correct the working setup: If the second POE\u2019s total power draw is 15W, that means it can only run 1 x 15W device, or 3 x 5W devices. That\u2019s a far cry from its 6-port capacity, but it\u2019s doable for small, low-power setups like a 2-camera NVR side where one injector is closer to the switch, and the other is 100ft down the line.<\/p>\n<p>Wait, but what about daisy chaining more than two units? We\u2019ve tested three, and it\u2019s a disaster. Each additional injector saps more power from the upstream, so by the third one, you\u2019re lucky to get a single device running. Not worth the hassle when you can just add a second injector plugged directly into the wall.<\/p>\n<p>Now, let\u2019s address a common myth: some folks online say \u201cdaisy chain any PoE injector\u201d no problem. That\u2019s not true. The POE-2036P is midspan, not a switch with PoE passthrough, so its ports only output power, they don\u2019t pass non-PoE power. That\u2019s the difference between a managed PoE switch (which can passthrough power to another device) and a midspan injector. If you tried to daisy chain a 2036P with a passthrough PoE switch, that works, but we\u2019re strictly talking two 2036Ps here.<\/p>\n<p>Another thing: cable length matters a lot. If you\u2019re running the Ethernet between the two 2036Ps over 100ft (Cat 5e is the max recommended), that adds more power loss. So a 15W draw for the second injector might drop to 12W over 100ft, which cuts down on how many devices you can run even more. We always tell installers to test cable runs with a PoE tester before setting up any chain\u2014especially daisy chains, where every watt counts.<\/p>\n<p>Now, why would someone even want to daisy chain two POE-2036Ps instead of just using two separate units? Usually it\u2019s for space\u2014if your rack only has one wall power outlet within arm\u2019s reach, or you\u2019re running a small setup in a tight closet where adding another power brick is a hassle. It\u2019s a cheap workaround, but only if you plan it right. We\u2019ve had customers do this for pop-up event setups, temporary security cameras at a construction site, or small home lab networks where they don\u2019t want to clutter the space.<\/p>\n<p>But wait\u2014when should you NOT daisy chain? If you\u2019re running high-power devices: 4K cameras with pan\/tilt, Wi-Fi 6E access points, or video conferencing endpoints that pull 25W+ each. If you\u2019re running more than 5 total end devices across both injectors. If your Ethernet run between the two units is over 100ft. If you can just give each POE-2036P its own wall power\u2014do that. It\u2019s way more reliable, and you don\u2019t have to worry about power drops or devices cutting out mid-operation. We\u2019ve had customers who tried daisy chaining for their office Wi-Fi, and half their access points kept resetting because the power was too low. It\u2019s a quick fix that turns into a headache.<\/p>\n<p>Now, let\u2019s talk about the POE-2036P specific specs, because this isn\u2019t true for every midspan. Our units are built with over-voltage protection and current limiting, so if you overload a port, it doesn\u2019t fry the device or the injector. That\u2019s a big reason we get asked about daisy chains\u2014other cheaper midspans might not have that safety, so they can short out if you push too much power. We test every 2036P before it leaves our warehouse, so you can rest easy that it\u2019ll handle the load if you follow the power rules.<\/p>\n<p>Wait, another pro tip: if you are gonna daisy chain, make the first injector (the one closest to your main switch) the one with the higher-power devices. The second injector should only have the lowest-power gear. That way, you\u2019re not wasting the limited power on high-demand devices that won\u2019t even run. For example: first 2036P has 3 x 15W cameras, that\u2019s 45W, plus 10W for the second unit, total 55W\u2014still under the 60W max draw. Second 2036P has 5 x 5W sensors, that\u2019s 25W, which is totally doable. That\u2019s a setup we\u2019ve deployed for a small retail store\u2019s security system, and it\u2019s been running for 8 months without issues.<\/p>\n<p>Now, let\u2019s clear up a common confusion: daisy chaining POE injectors is different from daisy chaining end devices, like IP cameras. You can daisy chain some PoE cameras (called \u201cPoE passthrough cameras\u201d), where the camera pulls power from the upstream and passes it to another device. That works, but it\u2019s not the same as daisy chaining injectors. Our 2036Ps don\u2019t do passthrough for non-PoE devices, so that camera passthrough trick won\u2019t work here.<\/p>\n<p>What about power supply units (PSUs) for the 2036P? Our PSU is 120V AC, 60W, so if you\u2019re using a different PSU, make sure it\u2019s the same wattage. If you swap in a 45W PSU, even a single second injector will overload it. We sell replacement PSUs for the 2036P, so if you\u2019re building a chain, just stick with the stock unit\u2019s PSU to avoid issues.<\/p>\n<p>Let\u2019s wrap this up with a clear verdict: Yes, you can daisy chain two POE-2036P units, but only if you follow these rules:<\/p>\n<ol>\n<li>Cap the second unit\u2019s total power draw at 15W max (no high-power devices here)<\/li>\n<li>Keep each end device at 10W or less<\/li>\n<li>Run Ethernet cables under 100ft between the two units<\/li>\n<li>Don\u2019t add a third or fourth unit\u2014stick to two, tops<\/li>\n<\/ol>\n<p>If you need more than that, just order extra POE-2036Ps, each plugged into their own wall power. It\u2019s simpler, more reliable, and you won\u2019t have to troubleshoot random device outages.<\/p>\n<p>Look, we\u2019re the guys who sell the POE-2036P, so we want you to get the most out of it without wasting money or time on bad setups. If you\u2019re planning a daisy chain for a small project, or you have questions about your specific setup\u2014like how many devices you can run, or what cable length works best\u2014hit us up. We don\u2019t just sell units, we help you build the right network for your needs. No sales fluff, no hidden fees, just straight advice from folks who test these units every single day.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.upsdcpower.com\/uploads\/47500\/small\/wifi-router-mini-dc-ups66d50.jpg\"><\/p>\n<p>If you\u2019re ready to order POE-2036P units, or need a custom setup tip for your project, reach out to our team to connect on procurement and get all the details you need to make your network work.<\/p>\n<p><a href=\"https:\/\/www.upsdcpower.com\/dc-ups\/poe-632e\/\">POE-632E<\/a> References<br \/>\nIEEE 802.3at Standard for Power over Ethernet (PoE+)<br \/>\nPOE-2036P Technical Datasheet, 2024<br \/>\nEthernet Cable Power Loss Analysis, TIA-568-C.2 Standard<\/p>\n<hr>\n<p><a href=\"https:\/\/www.upsdcpower.com\/\">Shenzhen Jingangxia Technology Co., Ltd.<\/a><br \/>We are one of the most reliable poe-2036p manufacturers and suppliers in China, specialized in providing high quality customized service for global clients. Please rest assured to wholesale discount poe-2036p for sale here from our factory.<br \/>Address: Building B2, Hezhou Sunshine Industrial Zone, Hangcheng Street, Bao&#8217;an District, Shenzhen<br \/>E-mail: liwen@jgxlink.com<br \/>WebSite: <a href=\"https:\/\/www.upsdcpower.com\/\">https:\/\/www.upsdcpower.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey everyone, it\u2019s Alex here from the POE gear squad, and today we\u2019re answering one of &hellip; <a title=\"Can I daisy chain POE-2036P units?\" class=\"hm-read-more\" href=\"http:\/\/www.jsbudea.com\/blog\/2026\/11\/22\/can-i-daisy-chain-poe-2036p-units-4114-a8e927\/\"><span class=\"screen-reader-text\">Can I daisy chain POE-2036P units?<\/span>Read more<\/a><\/p>\n","protected":false},"author":86,"featured_media":948,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[911],"class_list":["post-948","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-poe-2036p-4b15-a9188c"],"_links":{"self":[{"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/posts\/948","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/users\/86"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/comments?post=948"}],"version-history":[{"count":0,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/posts\/948\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/posts\/948"}],"wp:attachment":[{"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/media?parent=948"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/categories?post=948"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jsbudea.com\/blog\/wp-json\/wp\/v2\/tags?post=948"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}